This example demonstrates how to use OTL template & dymanic PL/SQL table containers for reading/writing PL/SQL tables from/to the otl_stream.
#include <iostream> using namespace std; #include <stdio.h>
#define OTL_ORA7 // Compile OTL 4.0/OCI7 #include <otlv4.h> // include the OTL 4.0 header file otl_connect db; // connect object
void plsql(void) { otl_stream s(1, // buffer size needs to be set to 1 in this case "begin " " pkg_test.prc_test(:t1<int,inout[100]>,:t2<char[32],out[200]>); " "end;", db // connect object ); s.set_commit(0); // Since there is no transactions, unset the stream auto-commit otl_int_tab<100> t1; // PL/SQL table of int[100] otl_cstr_tab<200,32> t2; // PL/SQL table of char[200][32]
t1.v[0]=1; // assign 1 to t1[0] t1.set_non_null(0); // specify that the value is not null t1.v[1]=2; // assign 2 to t1[1] t1.set_non_null(1); // specify that the value is not null t1.set_null(2); // set t1[2]=NULL t1.set_len(3); // set t1's length to 3
s<<t1; // write t1 into the stream, since it is input s>>t1; // read t1 from the stream since it is input/output s>>t2; // read t2 from the stream since it is output.
cout<<"T1_Len="<<t1.len()<<endl; for(int i=0;i<t1.len();++i) if(t1.is_null(i)) cout<<"T1["<<i<<"]=NULL"<<endl; else cout<<"T1["<<i<<"]="<<t1.v[i]<<endl; cout<<endl<<endl<<"T2_Len="<<t2.len()<<endl; for(int j=0;j<t2.len();++j) if(t2.is_null(j)) cout<<"T2["<<j<<"]=NULL"<<endl; else cout<<"T2["<<j<<"]="<<t2.v[j]<<endl; } int main() { otl_connect::otl_initialize(); // initialize OCI environment try{ db.rlogon("scott/tiger"); // connect to Oracle otl_cursor::direct_exec (db, "CREATE OR REPLACE PACKAGE pkg_test IS " " TYPE my_numeric_table IS TABLE OF NUMBER INDEX BY BINARY_INTEGER; " " TYPE my_varchar_table IS TABLE OF VARCHAR2(31) INDEX BY BINARY_INTEGER; " " " " PROCEDURE prc_test(v1 IN OUT my_numeric_table, v2 OUT my_varchar_table); " " " "END; " ); otl_cursor::direct_exec (db, "CREATE OR REPLACE PACKAGE BODY pkg_test IS " " " " PROCEDURE prc_test(v1 IN OUT my_numeric_table, v2 OUT my_varchar_table) " " IS " " BEGIN " " FOR i IN 1..v1.last LOOP " " v1(i) := v1(i)+100; " " END LOOP; " " v1(v1.last+1) := 0; " " v2(1) := 'Hello'; " " v2(2) := 'World'; " " v2(3) := '!!!'; " " END; " " " "END; " ); plsql(); } catch(otl_exception& p){ // intercept OTL exceptions cerr<<p.msg<<endl; // print out error message cerr<<p.stm_text<<endl; // print out SQL that caused the error cerr<<p.var_info<<endl; // print out the variable that caused the error } db.logoff(); // disconnect from Oracle return 0; }
T1_Len=4 T1[0]=101 T1[1]=102 T1[2]=NULL T1[3]=0 T2_Len=3 T2[0]=Hello T2[1]=World T2[2]=!!!
Copyright © 1996-2024, Sergei Kuchin, email: skuchin@gmail.com, skuchin@gmail.com .
Permission to use, copy, modify and redistribute this document for any purpose is hereby granted without fee, provided that the above copyright notice appear in all copies. THE SOFTWARE IS PROVIDED "AS IS" AND THE AUTHOR DISCLAIMS ALL WARRANTIES WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE.